SpecificationsThe Rapid Tester the flash point temperature/combustibility of flammable liquids.

Closed cup test temperatures from ambient to 572°F (300°C) are
 automatically controlled by the set-a-temp adjustable digitally
 preset target temperature circuitry. Integral digital LCD display,

NIST traceable thermometer, disposable fuel tank and electronic
timer are standard.

In accordance with:
 ASTM D 3278 “Flash Point of Liquids by Small Scale
Closed Cup Apparatus”

ASTM D 3828 “Flash Point by Small Scale Closed Tester”

ASTM D 4206 “Sustained Burning of Liquid

Mixtures by Setaflash Tester (Open Cup)”

BS 3900 Part A11 “Small Scale Test for Combustibility”
BS 3900 Part A13 “Rapid Test for Flash Point - Danger Classification”
BS 3900 Part A14 “Rapid Tests for Flash Point - Paints and Varnishes”
CPSC CFR 16-1500.43a “Federal Hazardous Substances Act Regulations”
DOT CFR 49-173.115 “Flammable, Combustible, and Pyrophoric liquids, definitions” IATA Resolution 618 Section 3.3.4 and 3.3.5

Attachment A
IP 303 Flash Point by Closed Rapid Tester”
ISO 3679 “Paints, Varnishes, Petroleum and Related Products - Determination of Flash Point - Rapid Equilibrium Method”

ISO 3680 “Paints, Varnishes, Petroleum and Related Products - Flash/No Flash Test - Rapid Equilibrium Method”

OSHA 29CFR 1910-106 “Program Directive 100”
OSHA 29CFR 1910-1200 “Hazard Communication”® is a semiautomatic instrument for determining

Characteristics Performance (RT-01)
Repeatability: 0.5°@ 70°C 2.0°@ 150°C
Reproducibility: 2.0°@ 70°C 7.5°@ 150°C
Test Time: 1 min below 212°F 1 min above 212°F (100°C)

Physical
Cup Type: RT-01 Closed RT-02 Open
Cup Material: Aluminum (316ss optional)

Dimensions: 15.0x3.4x6.3 in (38.1x8.64x16.25 cm)

Display: LCD digital and NIST traceable mercury-in-glass thermometer

Net Weight: 10 lbs (4.6 Kg)
Power Requirements: 115/230v, 50/60 Hz

Sample Size: RT-01 2 ml below 212°F
4 ml above 212°F (100°C) RT-02 2 ml

Temperature Range RT-01 -22° to 572°F
(-30° to 300°C) RT-02 Ambient to 212°F (100°C)

Warranty:

Rapid Tester instrumentation is warranted against defects in materials and workmanship for one year from the date of shipment and will be repaired or replaced at manufacturer’s option. This warranty is exclusive of shipping charges, consumable components, or misuse. The liability of the manufacturer is limited to such repair of replacement. No warranty of fitness for a particular purpose or liability for consequential or other damages shall be implied.

Note:

This Data Sheet contains only a general description of the Rapid Flash Point Tester. While uses and performance capabilities are described, under no circumstances should the product be used except by qualified, trained personnel and not until the instructions, labels, or other literature accompanying it have been carefully read, understood and the precautions therein set forth followed. Only they contain the complete and detailed information concerning this product. Do not use in hazardous areas. The Manufacturer reserves the right to alter design and/or specifications without notice.



 